Lined Elbow 45°

fluro product

DIMENSIONAL TABLE

Pipework (NB) ∅OD ∅ID ∅RF ∅P.C.D NH ∅H T A Min.
Lining tdk
Inches mm mm mm mm mm mm mm mm mm mm
1” 25 108.0 19 51 79.4 4 16.0 14.3 44 3.5
1.1/2” 40 127.0 34 73 98.4 4 16.0 17.5 57 3.5
2” 50 152.4 45 92 120.6 4 19.0 19.0 63 3.5
2.1/2” 65 177.8 55 105 139.7 4 19.0 22.2 76 3.5
3” 80 190.5 69 127 152.4 4 19.0 23.8 76 4.0
4” 100 228.6 92 157 190.5 8 19.0 23.8 102 4.0
6” 150 279.4 144 216 241.3 8 22.2 25.4 127 5.0
8” 200 342.9 192 270 298.4 8 22.2 28.6 140 6.0
10” 250 406.4 241 324 361.9 12 25.4 30.2 165 7.0
12” 300 482.6 296 381 431.8 12 25.4 31.8 190 7.0
14” 350 533.4 325 413 476.2 12 28.6 34.9 190 8.0

MATERIAL SPECIFICATION

Item Des. Material (standard) Material (optional)
SHELL ASTM A 234 Gr. WPB SS304, SS304L, SS 316. SS316L
SHELL SCHEDULE SCH.40 SCH.10, SCH.20, SCH.30, SCH.60, SCH.80, SCH.100, SCH.120, SCH.140, SCH.160
LINING PTFE ASTM D 1457. TYPE: III PVDF-ASTM D 3322, PP-ASTM D 4101, HDPE, ANTISTATIC PTFE
FLANGE ANSI B 16.5-ASA150# (MADE FROM IS 2062 PLATE) ASTM A105, SS304, SS304L, SS316, SS316L (ROTATING, FLANGE IS ALSO AVAILABLE ON REQUEST )
FLANGE RATING ASA150# CLS.300, CLS.600, BS10-TABLE D, TABLE E, TABLE F, TABLE H, TABLE J, & TABLE K, DIN STANDARD- PN6, PN10,PN16, PN25 & PN40

TESTING SPECIFICATION

  • 100% Visual Check/Dimensional Check
  • 100% Hydro Test at 29.9 kg/cm(g) for holding time of 3 Mins. as per ASTM F 1545 - 15A
  • 100% Spark Test at 10 kv after Lining
  • 100% Lining tdk. to be checked.(>80% of Flaring tdk.)